02750nas a2200241 4500000000100000008004100001260001600042100001600058700001100074700001600085700001600101700001700117700002100134700001700155700001600172700001800188700001900206245009200225300000700317490000700324520216300331022001402494 2018 d c-64415332311 aKumar Vinod1 aJha V.1 aKumar Vivek1 aYadav Ashok1 aKohli Harbir1 aYasuda Yoshinari1 aHorio Masaru1 aSahni Nancy1 aGupta Krishan1 aMatsuo Seiichi00aExisting creatinine-based equations overestimate glomerular filtration rate in Indians. a220 v193 a

BACKGROUND: Accurate estimation of glomerular filtration rate (GFR) is important for diagnosis and risk stratification in chronic kidney disease and for selection of living donors. Ethnic differences have required correction factors in the originally developed creatinine-based GFR estimation equations for populations around the world. Existing equations have not been validated in the vegetarian Indian population. We examined the performance of creatinine and cystatin-based GFR estimating equations in Indians.

METHODS: GFR was measured by urinary clearance of inulin. Serum creatinine was measured using IDMS-traceable Jaffe's and enzymatic assays, and cystatin C by colloidal gold immunoassay. Dietary protein intake was calculated by measuring urinary nitrogen appearance. Bias, precision and accuracy were calculated for the eGFR equations.

RESULTS: A total of 130 participants (63 healthy kidney donors and 67 with CKD) were studied. About 50% were vegetarians, and the remainder ate meat 3.8 times every month. The average creatinine excretion were 14.7 mg/kg/day (95% CI: 13.5 to 15.9 mg/kg/day) and 12.4 mg/kg/day (95% CI: 11.2 to 13.6 mg/kg/day) in males and females, respectively. The average daily protein intake was 46.1 g/day (95% CI: 43.2 to 48.8 g/day). The mean mGFR in the study population was 51.66 ± 31.68 ml/min/1.73m. All creatinine-based eGFR equations overestimated GFR (p < 0.01 for each creatinine based eGFR equation). However, eGFR by CKD-EPIwas not significantly different from mGFR (p = 0.38). The CKD-EPIexhibited lowest bias [mean bias: -3.53 ± 14.70 ml/min/1.73m(95% CI: -0.608 to -0.98)] and highest accuracy (P: 74.6%). The GFR in the healthy population was 79.44 ± 20.19 (range: 41.90-134.50) ml/min/1.73m.

CONCLUSION: Existing creatinine-based GFR estimating equations overestimate GFR in Indians. An appropriately powered study is needed to develop either a correction factor or a new equation for accurate assessment of kidney function in the Indian population.

 a1471-2369